caradoc question
-
Roberts wood light railwa
caradoc question
a friend of mine accuired a caradoc yesterday and whilst looking over it we noticed theres no water gauge glass on it so you'll be able to guess the next question ..... how do we know when its ran out of water? cheers
-
Big Jim
-
Roberts wood light railwa
-
Big Jim
People do top up the gas and water (if you have a water top up valve fitted) during a run. But it then becomes a bit 'suck it and see'. It depends how high the gas is turned up and how had the loco is working. As to how long things last.
I tend not to bother topping up with mine.
As you get used to a loco you will start to work out when to add more water or top up the gas.
Never top up a gas tank when the burner is lit.
I tend not to bother topping up with mine.
As you get used to a loco you will start to work out when to add more water or top up the gas.
Never top up a gas tank when the burner is lit.
- TonyW
- Driver

- Posts: 1357
- Joined: Fri May 16, 2008 9:25 am
- Location: North Wales
- Contact:
Errr.... No water = no steam = no pressure. I remember somebody telling me years ago that a boiler that runs dry will explode, yet he couldn't explain how exactly that might happen...Big Jim:110054 wrote:Pressure goes up and loco stops!
Tony Willmore
Rhos Helyg Locomotive Works: http://www.rhoshelyg.me.uk
Facebook: https://www.facebook.com/RhosHelygLocoWorks
Rhos Helyg Locomotive Works: http://www.rhoshelyg.me.uk
Facebook: https://www.facebook.com/RhosHelygLocoWorks
- Chris Cairns
- Driver

- Posts: 2372
- Joined: Mon Oct 29, 2007 7:25 pm
- Location: Glasgow, Scotland
I recently picked up a 2nd hand Caradoc that has been fitted with a water top up valve, and have pondered how this can be used properly without a working sight glass. I'm not a fan of the 'suck it and see' theory being used to operating full size locomotives with 2 working sight glasses.
On my Ragleth & Edrig I worked out that the boiler is full with 240 mls of water (up to the top of the safety valve bushing). The water level check valve effectively removes approx. 50 mls of water, so on my Edrig I fill the boiler full then remove 50 mls using a syringe with a piece of silicon tubing, and do not bother using the water level check valve. My Ragleth is a bit more fussy so I remove 53 mls of water.
As I only run on other's layouts or Garden Railways for now I just run on one tank full of gas which always runs out first leaving water in the boiler. If I complete more runs I go back through the process of filling up the boiler full then removing 50 (53) mls of water.
Only run my Caradoc on blocks so far (Group's running day next weekend) and removing 50 mls of water works OK here as well.
Having inadvertently run one of my Regner's dry (their sight glasses are very hit & miss and I was otherwise distracted and had forgotten to count how many laps I'd done prior to topping up the water) I can confirm the loco slows down with zero pressure indicated - in this case immediately turn off the gas and allow the loco to cool down naturally - Do Not Add Water
Chris Cairns
On my Ragleth & Edrig I worked out that the boiler is full with 240 mls of water (up to the top of the safety valve bushing). The water level check valve effectively removes approx. 50 mls of water, so on my Edrig I fill the boiler full then remove 50 mls using a syringe with a piece of silicon tubing, and do not bother using the water level check valve. My Ragleth is a bit more fussy so I remove 53 mls of water.
As I only run on other's layouts or Garden Railways for now I just run on one tank full of gas which always runs out first leaving water in the boiler. If I complete more runs I go back through the process of filling up the boiler full then removing 50 (53) mls of water.
Only run my Caradoc on blocks so far (Group's running day next weekend) and removing 50 mls of water works OK here as well.
Having inadvertently run one of my Regner's dry (their sight glasses are very hit & miss and I was otherwise distracted and had forgotten to count how many laps I'd done prior to topping up the water) I can confirm the loco slows down with zero pressure indicated - in this case immediately turn off the gas and allow the loco to cool down naturally - Do Not Add Water
Chris Cairns
- TonyW
- Driver

- Posts: 1357
- Joined: Fri May 16, 2008 9:25 am
- Location: North Wales
- Contact:
All of my locos are fitted with top-up valves, but only two recent purchases have sight glasses. An unreliable sight-glass is less use than no sight glass.
The method I use is to pump water in until the pressure gauge is back to zero after about 10 minutes of running. I find that this puts sufficient water in the boiler to continue the run but without filling it to the top, and that working pressure is regained reasonably quickly.
The method I use is to pump water in until the pressure gauge is back to zero after about 10 minutes of running. I find that this puts sufficient water in the boiler to continue the run but without filling it to the top, and that working pressure is regained reasonably quickly.
Tony Willmore
Rhos Helyg Locomotive Works: http://www.rhoshelyg.me.uk
Facebook: https://www.facebook.com/RhosHelygLocoWorks
Rhos Helyg Locomotive Works: http://www.rhoshelyg.me.uk
Facebook: https://www.facebook.com/RhosHelygLocoWorks
-
mikewakefielduk@btinterne
- Keith S
- Driver

- Posts: 1668
- Joined: Thu Feb 24, 2011 11:44 pm
- Location: Canada
They probably just believed that because that's what happens on a full-size locomotive-type boiler when the crown sheet isn't covered with water.TonyW:110078 wrote:Errr.... No water = no steam = no pressure. I remember somebody telling me years ago that a boiler that runs dry will explode, yet he couldn't explain how exactly that might happen...Big Jim:110054 wrote:Pressure goes up and loco stops!
However I have heard that it is very dangerous to attempt to put water into a model boiler which has run dry and is still red-hot inside. Somewhere on the internet I have seen pictures of a single-flue model locomotive boiler that was tested to destruction. It blew up like a rugby ball and the flue collapsed, but it still didn't explode!
-
Big Jim
-
Roberts wood light railwa
Who is online
Users browsing this forum: No registered users and 33 guests